Language
  • English
  • Español
  • ភាសាខ្មែរ
  • 中文
  • Tiếng Việt
  • 한국어
  • ไทย
  • हिन्दी
  • اردو
  • नेपाली
Northeast Texas Public Health District NetHealth
  • Home
  • Departments
    Environmental Health
    EH Overview
    Permits and Forms Library
    Apply & Pay Online
    Recent Health Inspections
    File A Complaint
    Women, Infants and Children (WIC)
    WIC Overview
    Clinic Locations
    Peer Dad / DREAM / Healthy Babies
    WIC Farmers Markets
    Mother Friendly Worksites
    Immunizations & Tuberculosis (TB)
    Imm Overview
    TB Control in Smith County
    Vaccines for Adults and for Children
    DSHS Requirements
    ImmTrac
    Public Health Preparedness
    PHEP Overview
    Disease Surveillance
    Sign Up for Emergency Alerts
    Basic Preparedness Tips
    S.T.E.A.R.
    Public Information Office (PIO)
    Monthly Board Meetings
    Public Information Request Form
    Charity Care Policy
    HIPAA Notices
    Laboratory Services
    Lab Overview
    Water Testing
    Milk Testing
    Clinical Testing
    Vital Statistics
    Births and Deaths in the City of Tyler
    Births and Deaths in Smith County
    Births and Deaths Outside of Texas
    Acceptable Forms of ID
    Community Wellness
    Wellness Overview
    Free Exercise Classes
    Sign Up for Your Free Mammogram
    We Can Help Manage Your Diabetes
  • Who We Are
    • Meet Our Team
    • Vision, Mission & Values
    • Community Partnerships
    • Media Interviews & Outreach Events
    • Event Calendar
  • Careers
    • Current Job Openings
    • Employee Benefits
  • Contact

Milk Testing

Critical for public health and dairy industry compliance, the NET Health Regional Laboratory offers milk testing services to ensure the safety and quality of dairy products.  We are one of only six State-certified milk testing laboratories.

!

Samples are not accepted for testing from private individuals.

Milk. It does the body good.

Milk haulers are probably one of the most important links between the milk producer, milk plant, state milk sanitarians and our laboratory. More than mere truck drivers, they are the judge of acceptable milk before it leaves the dairy; their sampling techniques are very important because the milk sample reflects the quality and composition of the milk in the dairyman’s bulk tank. 

Test results that our Laboratory obtains have a major influence on the dairyman, his herd and his family, since his milk supply must stay in substantial compliance with the laboratory test standards discussed below. These test results are all based on the sample that the milk hauler obtains. 

Maintaining proper temperature (0.0º - 4.5ºC) is essential to preventing microbial growth and ensuring that there are no chemical or physical changes in the samples until they are analyzed.  Collectors must also ensure that all pertinent information is recorded properly so that the samples will be accepted by the registered state milk sanitarians. This is due to the legal nature of the process, when collecting samples for regulatory purposes.

Types of Milk Testing

  • Bacterial Testing: Includes tests for standard plate counts, coliforms, and other potential contaminants in milk.
  • Composition Analysis: Evaluates fat content, protein levels, and other key nutritional components.

Sample Submission

  • Instructions: Guidelines are provided for properly collecting and submitting milk samples to maintain test accuracy.

Contact Information

  • Inquiries: For more details on testing services and procedures, contact the NET Health Regional Laboratory.

Laboratory Test Procedures for Raw and Retail Milk


Standard Plate Count

Milk and dairy products are generally very rich in nutrients which provide an ideal growth environment for many microorganisms. Therefore, all milk samples are carefully maintained with a temperature of 0.0º to 4.5ºC from collection until the samples arrive in our laboratory within 60 hrs from the time of collection. The standard plate count (SPC) method is the first test performed on a milk sample after it arrives in our laboratory. This test is used to evaluate the general sanitation of the dairyman’s equipment and the overall health of his herd. This method is one of the procedures used throughout the dairy and regulatory enforcement agencies for the determination of quality and the detection of microbial contamination for raw and retail (processed) milk. For a raw milk sample the total bacterial count must be less than or equal to 100,000/ml. For a retail product the total count must be less than or equal to 20,000/ml or gram. For frozen desserts the total bacterial count must be 50,000/gram or less.


Detection of Antibiotic/Drug Residues for Raw and Retail Milk

Common practice for management of livestock, including dairy animals includes antibiotic drug therapy. Residues of these drugs may enter the milk supply if the cow is continued to be milked. Regulations require that milk from the treated animal must be withdrawn for a prescribed time. When this is not followed, the contaminated milk containing the drug residues may be sent to the plants. Milk containing such antibiotics cannot be used for human consumptions, due to possibly triggering hypersensitivity reactions in susceptible individuals. Regulatory standards and customer specifications are met by our laboratory to ensure that milk from these antibiotic treated cows does not make it to market.



Raw Milk-Standard Plate Count Method

Somatic Cell Count – used to detect abnormal raw milk

Regulations require that raw milk for commercial sale be derived from one or more healthy cows. Abnormal milk includes milk from cows with mastitis. Screening and confirmatory tests estimate the number of somatic cells in milk. These cells, which include white blood cells and tissue cells are associated with the inflammation of the mammary glands, but are not intended for the diagnosis of mastitis. High counts can help the dairyman determine if there is a problem with the herd health, therefore affecting total milk production and his income. Somatic cell counts greater than 750,000/ml are reported to the State and will result in a warning letter or off-grade category, which will put a restriction on the sale of that particular dairy’s milk.


Freezing Point for Raw and Retail Milk

Pure water freezes at 0.0ºC. The average freezing point for normal raw milk has been accepted to be -0.540ºH. Our laboratory uses a cryoscope to determine the freezing point of the sample. The cryoscope analysis is used to determine whether or not water has been added. Regulations have tolerances for added water, and penalties are imposed on producer’s cryoscope reading under -0.525ºH.


Coliform Test for Retail Milk

This procedure is used by our laboratory to measure the quality of the practices used during the plant processing of retail dairy products. Coliforms detected from pasteurized products can often suggest improper pasteurization or post pasteurization contamination. Coliform tests are conducted following pasteurization primarily to detect bacterial recontamination of the milk. Retail milk products must have a coliform count less than 10/ml or gram. Frozen desserts must have a coliform count less than 40/gram to pass State regulation.


Phosphatase for Retail Milk

This test is used to determine that all retail products have been pasteurized properly by examining the products for alkaline phosphatase enzyme, which is normally destroyed during the pasteurization process. This flurometric procedure used must obtain a reading of less than 350mU/L, (3 micrograms) per liter (0.075% raw milk equivalent). This test procedure is capable of measuring down to 0.003% raw milk.


Aflatoxin for Raw Milk

Our laboratory also tests individual dairies for aflatoxin. Aflatoxin is a naturally occurring mycotoxin produced by certain strains of the molds Aspergillus which are often found in feed grains consumed by dairy cows. When this mold is consumed by dairy cattle, it can be metabolized and resides primarily in the milk. Aflatoxins are known carcinogens. FDA has set the following limits for Aflatoxin: Food and feed products-20ppb; Milk- 0.5ppb. Regulatory labs routinely screen raw producer samples for the presence of Aflatoxin to help the State monitor actionable levels. Dairy milk supplies with above-actionable levels are officially detained and removed from the market until subsequent testing indicates that the milk is either free of Aflatoxin or at below-actionable levels and the milk can be release for human consumption.


Milk Links: The links below will direct you to outside sources of information and take you away from our web site. These links are provided as a service and other sources of information. We do not necessarily imply any endorsement of or responsibility for ideas, opinions, data, or products viewed at these provided links.


  • United States Food and Drug Administration
  • Texas Department of State Health Services Milk and Dairy Division
  • www.whymilk.com
  • www.moomilk.com


Dairy Water Testing


All water must be of a safe and sanitary quality to be suitable for use in the dairy and plant operations.  Three testing procedures are used by our laboratory:  


P/A-Presence/Absence Test


MPN-Coliform MPN (Most Probable Number) Test.  This procedure detects the presence of coliform bacteria by the multiple tube fermentation.  


HPC-Heterotrophic plate count.  This method uses the pour plate method.


Water for milkhouse, milking operations and milk plant operations must be of a safe sanitary quality and practically free of microorganisms that could initiate spoilage. A polluted water supply, used in the rinsing of dairy utensils and containers, may be more dangerous than a similar water supply that is used for drinking purposes only. Bacteria grow much faster in the milk than in water because of the nutritional content of milk. Contamination can occur either directly, through product contact with the water itself, or indirectly, by microbes growing on nutrient residues on incompletely cleaned equipment surfaces.


NETPHD is certified by the Texas Department of State Health Services (DSHS) to analyze dairy water and also coolants (glycol, recirculated cooling water) used in the operation of dairy farms and milk plants.

Definitions:

  • Dairy water – supply water from a well
  • Glycol – a coolant used to cool down large tanks of milk
  • Recirculated water – water which is used to also achieve the cooling of large vats of milk


Acceptable Limits:

  • MTF – no coliform bacteria found; no E. coli found
  • HPC - <500 colony forming units (CFUs)/ml Under Construction

A Schematic of the Composition of Milk


Schematic of Milk.pdf

Northeast Texas Public Health District

815 N. Broadway Ave
Tyler, Texas 75702

903-535-0030

Website by GroupM7 Design

Quicklinks

  • Birth & Death Records
  • Careers
  • Environmental Health Application
  • Environmental Health Payment Form
  • Lab Testing
  • WIC Locations

Resources

  • Centers for Disease Control
  • Texas Department of State Health Services
  • Health & Human Services Commission

Social

  • YouTube
  • Facebook
  • Instagram
  • Podcast